DCN Next Generation Open Interface Release 2.4 Appendix DCN Wireless
en | 283
Bosch Communications Systems | 2007 February | MMI_AQ_INF | AQ041402
4. SYSTEM CONFIGURATION (SC) NOTIFICATIONS
4.1 Introduction
See [SRS_SCSIINF].
4.1.1 Unit/user event relations
UNIT-EVENT MATRIX
Event Update Notification
Connect a WAP SC_C_CONNECT_UNIT
Disconnect a WAP SC_C_DISCONNECT_UNIT
SC_C_DISCONNECT_UNIT ->For each unit connected to the
WAP
4.2 SC_C_BATTERY_STATUS
Purpose
Notifies the remote controller the battery status of a unit. This notification is send after the battery
status of a unit has been changed or after SC_C_BATTERY_STATUS_REQ is executed.
Notify structure with this update
The update uses the following structure:
typedef struct
{
UNITID tUnitId;
BYTE byBatteryLevel;
WORD wRemainingTime;
} SC_T_BATTERY_STATUS;
where:
tUnitId The unit identifier of a unit.
byBatteryLevel Level of the battery [%] from 0 to 100 %
When the unit has no battery the level will be 100
wRemainingTime Remaining time of the battery in minutes
When the unit has no battery the remaining time will be
0xFFFF
4.3 SC_C_BATTERY_INFO_SERIAL
Purpose
Notifies the remote controller the serial number of the battery located in the unit. This notification
is send after SC_C_BATTERY_INFO_REQ is executed.
Notify structure with this update
The update comes with the following structure:
typedef struct
{
UNITID tUnitId;
DWORD dwSerialNr;
} SC_T_BATTERY_INFO_SERIAL;
where:
tUnitId The unit identifier of a unit.
dwSerialNr Serial number of the battery located in the unit