Bosch DCN Next Generation Manuale Utente Pagina 268

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 296
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 267
DCN Next Generation Open Interface Release 2.4 Intercom
en | 268
Bosch Communications Systems | 2007 February | SRS_ICINF | Du110902
Related functions
IC_C_CLOSE_IC_APP
3.2.2 IC_C_CLOSE_IC_APP
Purpose
Indicates the CCU that the remote controller no longer requires updates from the IC application
inside the CCU.
Parameter structure for the function
The function has no additional parameters.
Response structure from the function
The function has no response parameters.
Error codes returned
IC_E_NOERROR
Related functions
IC_C_START_IC_APP
3.2.3 IC_C_SET_LINKS
Purpose
This function allows the remote controller to set special links.
Parameter structure for the function
The function requires the following structure as parameter:
typedef struct
{
IC_T_LINKINFO_LIST tList[IC_MAX_LINKS_IN_RFC];
} IC_T_LINKINFO_LIST;
with:
typedef struct
{
UNITID wSourceId;
UNITID wDestId;
} IC_T_LINKINFO_STRUCT;
where:
wSourceId The unitId of the initiator of the intercom call. If the wSourceId is
IC_C_UNASSIGNED_UNIT, then this is the last link in the list.
wDestId The unitId of the receiver of the intercom call
Response structure from the function
The function has no response parameters.
Error codes returned
IC_E_NOERROR
IC_E_WRONG_PARAMETER
3.2.4 IC_C_CLEAR_ LINKS
Purpose
This function allows the remote controller to remove all the existing special links between units.
Parameter structure for the function
The function has no additional parameters.
Response structure from the function
The function has no response parameters.
Error codes returned
IC_E_NOERROR