2. INTERNAL FUNCTIONING VOTING APPLICATION
The voting application present in the CCU is set up as an engine capable of handling
parliamentary kind of voting’s. For all voting rounds to be carried out, you can identify common
aspects for each different kind of voting.
The voting application uses the common aspects to control the voting requested. Some of these
common aspects are:
Subject of the voting
The kind of the voting (e.g. parliamentary voting with “Yes”, “No“ & Abstain” answers)
General setting (e.g. voting time limit, etc.)
More details on the complete parliamentary voting application can be found in the appropriate
user manuals.
2.1 Voting subject
The Voting subject is controlled by the remote function VT_C_DOWNLOAD_SUBJECT. This
remote function passes the subject text along with a motion number as subject identifier to the
CCU. The CCU in his turn uses the motion number to identify the subject handled.
2.2 Voting kind
The voting kind determines the kind of voting to run by the voting application. The voting kind is
controlled by the remote function VT_C_SET_VOTINGPARAMS. This remote function passes
the kind of the voting (e.g. "parliamentary"), the number of answer options (e.g. "3"), the answer
menu settings (e.g. "Yes, Abstain, No"), etc. to the CCU. More parameters to complete the
identification of the voting kind must be passed to the CCU. A complete list of parameters can be
found at the remote function description in section 3.2.8.
2.3 General Voting setting
The general voting settings are mostly common for multiple voting rounds (done over different
kind of voting’s). These settings include settings like:
Voting time limit
Shows how many minutes and seconds the delegates have to complete their vote.
Voting LED’s
Shows the vote done using the LED’s on the delegate's unit or use one of the secret
voting sequences available.
First vote counts
Informs that the first vote entered (TRUE) or the last vote entered (FALSE) by the
delegate counts.
Detailed information about all the general voting settings can be found at the description for the
remote function VT_C_SET_GLOBAL_SETTINGS (section 3.2.9).
2.4 Communication settings
Not mentioned by the common aspects are the communication settings. These settings are used
to control how the communication of the results should take place. The results can be sent to the
remote controller using update notification (VT_C_RESULTSNOTIFY), or the results are not
automatically sent to the remote controller. In the latter case the remote controller must collect
the results using remote function (VT_C_GET_RESULTS).
Besides the selection of collecting the results (automatic of manual), these settings also includes
the way results could be received. A selection can be made to receive the results compressed or
normal. The next section explains the compressed result structure in more depth.