DCN Next Generation Open Interface Release 2.4 AT
en | 257
Bosch Communications Systems | 2007 February | SRS_ATINF | Du100902
APPENDIX B. ERROR CODES
Responses returned upon a remote function request contain an error field (‘wError’). In this
appendix an overview is given of the possible errors and their values.
Attendance Registration Error code Value: Dec Hex
Explanation
AT_E_NOERROR
0 0x000
The execution of the remote function was successful.
AT_E_APP_NOT_STARTED
2305 0x901
The remote controller has not called the AT_C_START_AT_APP
yet. Therefore any remote function call to the attendance
registration application fails with this error.
AT_E_STORE_SETTING_FAILED
2306 0x902
Settings or a combination of settings is not correct.
AT_E_HANDLE_IDENTIFICATION_FAILED
2314 0x90A
The eventId, the ID-card code and/or length of PIN-code are not
correct to handle the requested action.
AT_E_SETTING_NOT_CORRECT
2315 0x90B
Settings are not correct to handle the requested action.
AT_E_INCONTROL_OTHER_CHANNEL
2316 0x90C
The AT_C_START_AT_APP function could not finish successfully
because the attendance application is already controlled by another
remote controller using another channel.
AT_E_INCONTROL_THIS_CHANNEL
2317 0x90D
The attendance application is already under control by this remote
controller (on the same channel). Probably you have called the
AT_C_START_AT_APP function twice.
AT_E_INMONITOR_THIS_CHANNEL
2318 0x90E
The attendance application is already monitored by this remote
controller (on the same channel). Probably you have called the
AT_C_START_AT_APP function twice.
AT_E_NOT_INCONTROL
2319 0x90F
The remote function is not allowed, because this remote controller
has no control over the attendance registration application.
AT_E_CHANGE_NOT_ALLOWED
2321 0x911
A change of setting (even if they are the same as the previous call)
is not allowed, because attendance registration and/or access
control is currently active. Or the setting is present contact
(AT_C_PRESENTCONTACT), but no external contact is configured
as present contact in SI (see SRS_SCSIINF)
AT_E_ACTIVATION_NOT_ALLOWED
2322 0x912
The settings made by the remote function
AT_C_STORE_SETTING are conflict with the activation or
deactivation of attendance registration and/or access control. See
chapter 2 for more information.
AT_E_ILLEGAL_CONTROL_TYPE
2333 0x91D
The control-type passed to the function AT_C_START_AT_APP is
not within range of valid values (see Appendix A for the correct
control-type values).
AT_E_ILLEGAL_EVENT
2334 0x91E
The event-type passed to the function
AT_C_HANDLE_IDENTIFICATION is not within range of valid
values (see Appendix A for the correct event values).
AT_E_ILLEGAL_ARRAY_SIZE
2335 0x91F
The fill-level passed along with the function
AT_C_HANDLE_IDENTIFICATION exceeds the maximum array
Vedere la pagina 256