DCN Next Generation Open Interface Release 2.4 Text Status Display
en | 207
Bosch Communications Systems | 2007 February | SRS_LDINF | Du080902
3. REMOTE FUNCTIONS
3.1 Introduction
This chapter describes the remote functions used to configure the Text & Status Display
application on the CCU.
3.1.1 Remote function item explanation
Each description consists of the following items:
Purpose
A global description of the purpose of the function.
Parameter structure for the function
The input parameters needed to fulfill the function. When the function requires no
parameters, no structure is described here. The type definitions of the basic types used to
build up the input parameter structure are given in [SRS_INF].
Response structure from the function
The output information coming from the function called. This information is only valid when
the ‘wError’ field of the received response information equals LD_E_NOERROR.
Error codes returned
The possible error values returned in the ‘wError’ field of the response information for this
remote function. All different error codes are described in Appendix B.
Update notifications
The update notifications that are generated during the execution of the remote function.
When there are no notifications generated, this part will be omitted.
Related functions
The related function in conjunction with the function described. It refers to other remote
functions and to related update notifications. When there are no related functions, this part
will be omitted.
3.2 LD General functions
3.2.1 LD_C_START_LD_APP
Purpose
This function indicates the CCU that the remote controller wants to communicate with the LD
application inside the CCU. It is now impossible for another remote controller (e.g. DCNNG
Control PC) to gain control of the application. After this function has been called, the remote
controller will receive update notifications from the LD application (see section 4.1.2).
When the execution of this function is omitted, all other remote functions will have no effect
and will return an error code (LD_E_APP_NOT_STARTED).
Parameter structure for the function
The function has no additional parameters.
Response structure from the function
The function has no response parameters
Error codes returned
LD_E_NOERROR
LD_E_INCONTROL_OTHER_CHANNEL
LD_E_INCONTROL_THIS_CHANNEL
Related functions
LD_C_STOP_LD_APP