DCN Next Generation Open Interface Release 2.4 Voting
en | 181
Bosch Communications Systems | 2007 February | SRS_VTINF | Du040905
bOpenVoting = FALSE;
wInterimResultType = VT_C_INT_RES_NONE;
More information about the parameters can be found in section 3.2.8.
General voting
settings
The general voting settings consists of many parameters which have
the following default values:
wVotingLedMode = VT_C_LED_SHOWVOTE;
wPresentVotes = VT_C_100_PRESENT_KEY;
bShowVoteTimer = FALSE;
wVoteTimerLimit = 0;
bReserved1 = FALSE;
bAutoAbstain = FALSE;
bReserved2 = TRUE;
bVoteWeightingOn = FALSE;
bReserved3 = FALSE;
bFirstVoteCount = FALSE;
More information about the parameters can be found in section 3.2.9.
2.5.1 Standalone settings
During startup of the DCN Next Generation-system (power-on) the voting settings are set to their
initial values as described in §2.5.
However, when the DCN Next Generation-system was controller by a Remote Controller, and
new settings were enabled. After stopping the voting application (Call to function
VT_C_STOP_APP) some voting settings remain active during the standalone period. These
settings are:
Parameters Value
VT_C_SET_GLOBAL_SETTING remote function
wVotingLedMode This setting remains unchanged.
wPresentVotes In case VT_C_100_AUTHORISED_VOTES was
selected, the value of ‘wPresentVotes’ will change
to VT_C_100_VALID_VOTES.
For the others of ‘wPresentVotes’, the settings
remains unchanged.
bFirstVoteCounts This setting remains unchanged.
All other settings will return to their default values as described in §2.5.
The settings remain valid until either the power is turn off, or a remote controller is started, which
changes the settings.
2.6 Allowed settings without delegate-database present
The standard use of the voting application will be in combination with a downloaded delegate-
database.
However, it is possible to start a voting round without a downloaded delegate-database. In this
case the parameter value ranges are limited, because some settings require the presence of a
delegate-database.
In the table below an overview is given of the parameters with reduced setting due to the
absence of the delegate-database. The table shows the parameters of the remote functions
VT_C_SET_VOTINGPARAMS and VT_C_SET_GLOBAL_SETTINGS. When a parameter is not
present in the table, the value range, as described with the remote function, remains valid.
Parameters Value
VT_C_SET_VOTINGPARAMS remote function
bOpenVoting Only a closed voting is valid, therefore FALSE
wInterimResultType VT_C_INT_RES_NONE
VT_C_INT_RES_TOTAL
VT_C_INT_RES_TOTAL_PC_ONLY
VT_C_SET_GLOBAL_SETTING remote function