K2200 Series | Installation Guide | 6.0 Configuration and Testing EN | 51
Bosch Security Systems | 7/03 | 17375 1.3 / 46513C
Printer Specification
An 80-column dot matrix printer with a serial
interface is required. The serial interface must be set,
using switches and/or jumpers with the following
parameters:
• 4800 baud
• 8 data bits, 2 stop bits
• No parity
• Hardware handshake using DTR/CTS. When
the printer is busy, it should force DTR, usually
pin 20, low.
• The printer must be capable of receiving at least
82 characters after a busy signal is sent (DTR
going low).
Readykey
have used the EPSON LX series and the
OKI Data Microline 182 printers successfully in the
past.
Baud Rate
You must make sure that the baud rate at the master
door controller is set to 4800. See the INST
command (see Section 6.1.5 INST Command).
Printer Cable
The following cable is required:
Use 24 AWG (0.5 mm), 4-conductor, unshielded
cable, maximum length: 50 ft. (15 m)
Figure 33: Printer Cable Pin-outs
Readykey
K2200 Printer
5-pole terminal block 25-pin male D-type connector
TXD ———— 3 RX
CTS ———— 20 DTR
RXD
DTR
GND ———— 7 Signal Ground
Testing the Printer
Once the printer is connected and the parameters set
as above, switch on the printer and make sure that it
is 'on-line'. If everything is set correctly, you should
immediately get some transactions printed out. If
not, pres the reset button on the controller.
Possible Problems
If you do not get immediate printing of events, check
the following:
• Check the cable - it should be wired as described
above.
• Check that the printer's serial port is being used.
Most printers are sold with a parallel port as
standard - the serial port is supplied as an add-on
option. There may be a switch that selects which
port the printer should use.
• Check that both the door controller and the
printer are set to a baud rate of 4800. If you get
random characters on the printer, the baud rates
may not match. The printer will usually have
DIP switches or jumpers that need to be set to
give the correct baud rate. Always switch off the
printer before you change any settings.
• If you get normal printout but after one or two
pages the lines break up or you get random
characters, the 'handshaking' may not be
working. Check that the printer is using pin 20
for its DTR signal. Some printers allow you to
select a different pin number (often pin 11).
6.2.2 PC Interface Kit
Description
Readykey for Windows 16/32:
When an access control system is administered from a
PC, a PC interface kit is used to connect the PC to the
door controller. This involves connecting an interface
unit to the PC, along with a desktop key reader, and
connecting this, via a 4-conductor cable, to a small line
driver unit plugged into the door controller.
See the installation documentation for each
administration system for connecting the interface unit
to the PC and establishing communications.
This section describes the installation of the line driver
at the door controller.
You
cannot
use any other type of communications devices
such as line drivers, dial-up modems, etc
Cable Specification
Use multi-stranded, unshielded, 4-conductor 24 AWG (0.5 mm) signal cable.