Bosch K2200 Series Guida di Installazione Pagina 42

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 41
K2200 Series | Installation Guide | 6.0 Configuration and Testing EN | 42
Bosch Security Systems | 7/03 | 17375 1.3 / 46513C
6.1.4 SYSTEM START Command
1. From the CMD prompt, type SYSTEM START
and press [ENT]. (Press [SPC] between SYSTEM
and START).
CMD SYSTEM START
2. This message will appear briefly:
ERASE ALL DATA
Type [Y] and press the [ENT] key.
3. These two messages are displayed as the memory
is cleared.
ERASING USE DATA
and
ERASING SYS DATA
End of process. Proceed to the INST Command
section.
Note:
The SYSTEM START command will end at
the first prompt of the INST command.
6.1.5 INST Command
For a Standalone Master Controller (no software
used):
Option Switches (Standalone Master Controller)
The option switches are fitted at the bottom right of
the circuit board.
For a Master Controller, the top 3 switches must be
set as shown in Figure 30. Switches 1 to 3 should be
set to in Figure 30.
Figure 30: Master Controller DIP Switches
1. At the CMD prompt, type in INST and press the
[ENT] button.
CMD INST
2. At PC ADMIN USED, press [N].
PC ADMIN USED N
Press [ENT] to save, press [NXT] to go on.
3. At MASTER DC, press [Y].
MASTER DC Y
Press [ENT] to save, press [NXT] to go on.
4. Set the POLL table for other salve controllers.
To poll controller 2, press the 2 and the [ENT]
key.
POLL ---
Press [ENT] to save, press [NXT] to go on.
5. Present a key to the faceplate reader. Numbers
will appear.
E0 KEY 00000000
Press [ENT] to save, press [NXT] to go on.
6. A password can be set to further protect the
Master Key. Type in the password (8 characters
max).
PASSWORD
Press [ENT] to save, press [NXT] to go on.
7. This is an identity for the master key. If you print
transactions, this identity will appear against
editor operations and alarm acknowledgements.
i.e - MASTER.
ID MASTER
Press [ENT] to save, press [NXT] to go on.
8. This allows the entry of a 12-character name
when adding keys. Type in Y.
ALPHA ID Y
Press [ENT] to save, press [NXT] to go on.
9. For the PRINTER TYPE:
Type 0 if you are using an Epson or IBM
compatible p
Type 1 if the printer is an OKI Microline.
PRINTER TYPE 0
Press [ENT] to save, press [NXT] to go on.
10. Sets the format in which dates appear in the
system:
Type 0 for 'dd-mm-yy' (European style).
Type 1 for 'mm-dd-yy' (US style).
DATE FORMAT 1
END OF SETUP. Press [ESC] to exit back to CMD
prompt.
Vedere la pagina 41
1 2 ... 37 38 39 40 41 42 43 44 45 46 47 ... 59 60

Commenti su questo manuale

Nessun commento