36 en | Installing AMC2 4W | Installation manual
F.01U.024.965 | V 0.1 | 2006.03 Bosch Sicherheitssysteme GmbH
5.6.2 RS-485 Four Wire Connection
Fig. 5.11 Connection scheme of an RS-485 four wire connection
Fig. 5.12 Settings for RS-485 four wire connection
i
NOTE!
A complete connection diagram of the RS-485 host interface is
shown in chapter Section 7.1 Connecting Diagrams of this docu-
mentation.