D9412GV2/D7412GV2 | Operation and Installation Guide | 3.0 Overview
10 Bosch Security Systems, Inc. | 7/09 | F01U003641-04
3.1.1 Parts List
The D9412GV2 andD7412GV2 Control Panels are
shipped assembled from the factory with the following
parts:
Literature Pack
• D9412GV2/D7412GV2 Program Record Sheet
(P/N: F01U003635)
• 9000/G/GV2 Series Technical Service Note: UL
Smoke Detector Compatibility (P/N: 33284)
• 7000/9000 Series Point Chart Label
(P/N: 79-06660-000)
Assembly
• PC board
• Faceplate shield
• Mounting skirt
• One #6 x 1/4-in. screw
3.1.2 Parts Available by Separate Order
Order the following components separately to
complete a basic eight-point installation.
The D1260 and D1260B Keypads must
have firmware version 1.03 or higher for
use with the D9412GV2 and D7412GV2.
• D1255B, D1255, D1256, D1260, D1260B
Keypad, or D720 Keypad
• D1255RB Fire Keypad, D1256RB Fire Keypad, or
D1257RB Fire Alarm Annunciator
• D1640 Transformer
• D126 or D1218 Battery
• D161 or D162 Phone Cord (order two cords if
using the D928 Dual Phone Switcher)
• D8103, D8108A, or D8109 Enclosure
Configured packages are also available. Please
consult the Bosch Security Systems, Inc. Product
Catalog.
The following literature is available in a separate
literature package for dealers.
• D9412GV2/D7412GV2 Operation and Installation
Guide (P/N: F01U003641)
• D9412GV2/D7412GV2 Approved Applications
Compliance Guide (P/N: F01U003639)
• D9412GV2/D7412GV2 Program Entry Guide
(P/N: F01U003636)
•
D9412GV2/D7412GV2 Program Record Sheet
(P/N: F01U003635)
The D9412GV2/D7412GV2 Troubleshooting Guide is
available in hard copy only (P/N: F01U011024),
CD-ROM only (P/N: F01U012325), or hard copy with
enclosed CD-ROM (P/N: F01U012326).
3.2 Accessories
Refer to the Bosch Security Systems, Inc. product catalog for additional information.
Table 3: Compatible Accessories
3
Model Title UL 864 Fire Intrusion
D122/D122L Dual Battery Harness X X X
D125B Powered Loop Interface Module X X X
D127 Reversing Relay X X X
D129 Dual Class A Initiation Circuit Module X X X
D130 Relay Module X X X
D185 Reverse Polarity Module X X
D192G Bell Circuit Supervision Module X X X
D279A
Independent Zone Control (On-Board and OctoPOPIT
Points)
X
D720 Keypad (Area LED) X X
D720R LED Keypad (red) X X
D720W LED Keypad (white) X X
D928 Dual Phone Line Switcher X X X
D1255RB Fire Keypad X X X
D1256RB Fire Keypad X X X
D1257RB Fire Alarm Annunciator X X X
D1218 12 V, 17.2 Ah Rechargeable Battery X X X
D1255/D1255B Keypads (General Purpose) X X
D1255R Text Keypad (red) X X
Commenti su questo manuale