Security Escort | Installation and Setup Guide | 2.0
E
ui
ment Estimation
EN | 16
Bosch Security Systems | 1/09 | 33831E
2.2 Pre-Bid Equipment
Estimation
The pre-bid equipment estimation is
performed prior to bidding the
installation. At this point, it must
be determined what type of coverage is
desired, and where the coverage is
required. For example, the amount of
equipment required for a full-coverage
(indoor and outdoor) system in a
multi-building application is greater
than an installation that requires
outdoor only coverage. The customer
should be consulted and the areas of
most concern should be given special
consideration.
2.2.1 Initial Equipment Estimate
Number of Indoor Receivers
To estimate the number of indoor
receivers, first read Section
2.3.2
Indoor Receiver Installation. Assume
the receivers are placed on a grid
with a maximum spacing of 25 m (80
ft.) between receivers for standard
construction. In multi-floor
applications the receivers on each
floor must be placed directly above
the receivers on the floor below (this
is required for proper floor-to-floor
location).
For example, to determine the number
of receivers required to protect a
building of standard construction of
60 m x 30 m (200 ft. x 100 ft.) and
four floors:
1. To determine the number of
receivers in each direction, divide
each dimension of the building by
25 m (80 ft.), drop the remainder,
and add 1.
For example:
• 60 m/25 m = 2.4, becomes 2, add
1 = 3
(200 ft./80 ft. = 2.5, becomes
2, add 1 = 3)
• 30 m/25 m =1.2, becomes 1, add 1
= 2
(100 feet/80 feet =1.25, becomes
1, add 1 = 2)
2. To determine the number of
receivers required per floor,
multiply the number of receivers in
one direction by the number of
receivers in the other direction:
(3 times 2 = 6) 6 receivers per
floor
3. To determine the total number of
receivers, multiply the number of
receivers per floor by the number
of floors:
(6 times 4 = 24) 24 receivers for
the building
Each floor would require 6 receivers,
resulting in a total of 24 receivers
to protect this building.
For the best location accuracy,
consistent receiver spacing is
important. Do not place receivers
significantly closer in one section of
a building than another section.
Figure 2: Determining the Number of Indoor Receivers Required
1
60 m
200 ft.
25 m
80 ft.
25 m
80 ft.
30 m
100 ft.
1 - Receivers (6)