5.4.3 Grounding and Shielding the Extension Interface
Fig. 5.5 Location of ground jumper bottom side
Jumper B connects the internal ground of the AMC2 4W to the
RS-485 ground of the slave interface. Jumper B shall only be
set (B2) if the AMC2 4W powers all other peripheral devices
which are directly connected to the AMC2 4W.
5.5 Connecting Power Supply
Connect the power supply to the 7-pin pluggable screw connec-
tor labeled with POWER on the upper case.
i
NOTE!
A complete connection diagram of the power supply connector
is shown in Figure 7.6.