DS7400XiV4-EXP | Reference Guide | 5.0 Programming the Control Panel EN | 89
Bosch Security Systems | 1/05| 4998154963B
Table 128: Area (Partition) Assignment
Selection Options
Select Option Value
Belongs to Area 1
0
Belongs to Area 2 1
Belongs to Area 3 2
Belongs to Area 4 3
Belongs to Area 5 4
Belongs to Area 6 5
Belongs to Area 7 6
Belongs to Area 8 7
Follows all areas 8
5.9.39 Dual Phone Line/Bell Supervision Module Output Programming
The Dual Phone Line/Bell Supervision Module is the DS7420i. See Section 2.4 Options for more information.
When in Central Station or Local Commercial Fire Mode, this address is forced to a specific value (see When
Central Station Commercial Fire Mode is Chosen and When Local Commercial Fire Mode is Chosen on page 51 for more
information).
Address: 4021
Data Digit:
Data Digit 1: ____ (see Table 129; default = 0)
Data Digit 2: Must = 0
Selections: 0 through 9
Table 129: Program Address 4021, Data Digit 1 Selections
Selections for Data Digit 1
Select Options 0 1 2 3 4 5 6 7 8 9
Disabled
Bell Monitor
Phone Line 1 Monitor
Phone Line 2 Monitor
Alarm Output on line fault
5.9.40 Call-Out Timer Programming
This section allows you to define the Hour and Minute
for the Communicator Test Report and Remote
Programmer Call-Out.
The default time for the Communicator Test Report to
be sent and for the control panel to call the Remote
Programmer is Midnight.
Test Report Hour
Address: 4022
Data Digit:
Data Digit 1: ____ (default = 0)
Data Digit 2: ____ (default = 0)
Selections: 0 to 2 for Data Digit 1; 0 to 3 for Data
Digit 2
Default: 00