Communication_T2413488907_2011830T1535_EMEA_en-US_print_RC9.09d_dm15ein_DatabookPDF
PA and Emergency Sound | Plena Public Address Solutions | 25
•
PC audio (cinch) input
•
Priority input
•
Master (XLR) output
•
BGM (XLR) output
•
Emergency signal input
•
Two trigger inputs
•
RS-232 (DE-9)
•
Three (cinch) CD, tape, aux inputs
•
Six 100 V speaker outputs
•
24 VDC output
•
24 VDC input
•
Three control inputs
•
Ground screw
•
IEC mains socket
Certifications and Approvals
Region Certification
Europe CE
Safety acc. to EN 60065
Immunity acc. to EN 55103-2
Emission acc. to EN 55103-1
Installation/Configuration Notes
LBB 1925/10 rear view
Parts Included
Quantity Component
1 LBB 1925/10 PLENA System Pre-amplifier
1 Power cord
1 Set of 19”mounting brackets
1 Plena CD
1 Installation and User Instructions
Technical Specifications
Electrical
Mains power supply
Voltage 230/115VAC, ±15%, 50/60 Hz
Current inrush 230/115 VAC, 1.5/3 A
Max power consumption 25 VA
Battery power supply
Voltage 24 VDC, +10% / -15%
Mains power supply
Current max 1 A
Performance
Frequency response 50 Hz to 20 kHz (+1 / -3 dB)
Distortion <0.5%
Bass control ±10 dB @ 100 Hz
Treble control ±10 dB @ 10 kHz
Channel separation >70 dB @ 1 kHz
Priority mute >40 dB
Dynamic range 100 dB
Mic/line input 1 x
Connectors 5‑pin DIN, 3‑pin XLR, balanced, with
phantom power
Sensitivity 1 mV (mic), 200 mV (line)
Impedance >1 kohm (mic); >5 kohm (line)
S/N (flat at max volume) >63 dB (mic); >70 dB (line)
S/N (flat at min volme/muted) >75 dB
CMRR >40 dB (50 Hz – 20 kHz)
Headroom >25 dB
Speech filter -3 dB @ 315 Hz, high-pass,
6 dB/oct
Phantom power supply 16 V via 1.2 kohm, (mic mode only)
Line input 3 x
Connector Cinch, stereo converted to mono, unbal-
anced
Sensitivity 200 mV
Impedance 22 kohm
S/N (flat at max volume) >70 dB
S/N (flat at min volume/muted) >75 dB
Headroom >25 dB
Master output 1 x
Connector 3-pin XLR, balanced
Nominal level 1 V
Impedance <100 ohm
Tape output 1 x
Connector Cinch, 2 x mono
Nominal level 350 mV
Impedance <1 kohm
Headphone output 1 x
Connector 6.3 mm jack stereo, signal mono
Nominal level 3 V
Impedance <100 ohm
Zone relays 5 A
Contacts voltage 250 V
Contacts current 8 A
Interconnection input / emer-
gency
1 x
Connector 3-pin XLR, balanced
Sensitivity 200 mV (interconnection),
100 mV to 1 V adjustable (emergency)
Impedance >10 kohm
www.boschsecurity.com Bosch Security Systems B.V.
1